L(797)
CASE 9 As for case 8 but with allowance for heat
capacity of metal
GROUP 1. Run title
TEXT(Case 9; Allowance For Metal Capac
TITLE
User-defined variables:
REAL(CAPM,COEF1O,COEF2O,COEFMO)
CAPM=0.1;COEFMO=CAPM/DELT
COEF12=COEF1*COEF2/(COEF1+COEF2+COEFMO)
COEF1O=COEF1*COEFMO/(COEF1+COEF2+COEFMO)
COEF2O=COEF2*COEFMO/(COEF1+COEF2+COEFMO)
Arrange that metal temperature, named METL, occupies
store with index 1 above 2NDH and 2 above 1STH.
SOLVE(C1);NAME(C1)=METL;TERMS(METL,N,N,N,Y,N,N)
FIINIT(1STH)=T1IN;FIINIT(METL)=0.5*(T1IN+T2IN)
COVAL(INLET1,METL,ONLYMS,SAME)
Repeat the COVALs using COEF12, which has changed
since it was calculated for case 8.
COVAL(NEPLUS,1STH,COEF12,LOCNE)
COVAL(NEMINUS,2NDH,COEF12,LOCNE)
Connect shell fluid with old metal
PATCH(NEO2,VOLUME,1,NX,1,NY,1,NZ,1,LSTEP)
COVAL(NEO2,1STH,COEF1O,LOCNE)
Connect metal with shell fluid
PATCH(NEM2,VOLUME,1,NX,1,NY,1,NZ,1,LSTEP)
COVAL(NEM2,METL,COEF1O,LOCNE)
Connect tube fluid with old metal
PATCH(NEO1,VOLUME,1,NX,1,NY,1,NZ,1,LSTEP)
COVAL(NEO1,2NDH,COEF2O,LOCNE)
Connect metal with tube fluid
PATCH(NEM1,VOLUME,1,NX,1,NY,1,NZ,1,LSTEP)
COVAL(NEM1,METL,COEF2O,LOCNE)
Transient for metal
COVAL(NEOLD,METL,CAPM/DELT,LOCNE)
LSWEEP=50
PLOT(TABMAP,METL,0.0,10.0)
PLOT(TABYEQ3,METL,0.0,10.0)
PLOT(PASS1,METL,T2IN,T1IN)
PLOT(PASS2,METL,T2IN,T1IN)
PLOT(PASS3,METL,T2IN,T1IN)
PLOT(PASS4,METL,T2IN,T1IN)
PLOT(PASS5,METL,T2IN,T1IN)
PLOT(TIMEPLOT,METL,T2IN,T1IN)