Mesh generation in GeoGrid: Geometry display, Boundary condition designation
Set-up in VR-Editor: Geometry, Inlet, Outlet
- Inlet conditions: Main inlet 5m/s at 20 deg C, left secondary inlet 2m/s at 15 deg C, right secondary inlet 2 m/s at 25 deg C.
 - Outlet condition: Pressure fixed to atmospheric.
 - Fluid: Air using the Ideal Gas Law
 - Turbulence: KECHEN
 - GCV multi-block, 5 blocks
 
Results viewed in VR-Viewer: Vectors on centre-line, Cross-stream vectors, Temperature contour on centre-line, Temperature iso-surface, Streamlines
Results viewed in TECPLOT: Vectors on centre-line, Temperature contour on centre-line, Temperature iso-surface, Streamlines